Romex wiring in garage | Information by Electrical Professionals for ...
May 8, 2015 · I'm buying a house and there is romex wiring run through the garage. The installation was approved by the township in 1987 when it was installed. Current standards …
That old Romex question again. | Information by Electrical ...
Mar 12, 2022 · Hello all. Got a question. I am wiring an office building for a family member's used car lot. The building was a two story split level residential home with a basement that is being …
Romex | Information by Electrical Professionals for Electrical ...
Sep 6, 2013 · In the code book it says that you can install Romex if permitted as a Type 3, 4 or 5 building, but if it is permitted as a type 1 building you can not install Romex. Although IF the …
Romex in metal studs | Information by Electrical Professionals for ...
Feb 16, 2004 · Re: Romex in metal studs 15 years ago I spent all my time wiring apartments and condos almost all NM and metal studs. I still use NM, mostly for temps and we do some …
Romex in conduit attached to an enclosure (indoors), fastening ...
Dec 17, 2024 · When using conduit to protect Romex before it enters an enclosure - for example, coming up out of the crawlspace, up an un-finished wall to a disconnect - what fastening …
Garage romex protection | Information by Electrical Professionals …
Mar 29, 2010 · Where in the code is it required, (or not) the need to protect NM cable run in a garage, horizontally through bored holes in stud runs that are exposed (not covered with …
Romex exposed under covered patio | Information by Electrical ...
Nov 6, 2024 · I'm working on making corrections on a residential inspection report for the sale of a home, one of the repairs the home inspector noted was the exposed romex running under a …
NMC (ROMEX) SUPPORT AND SECURE | Information by Electrical ...
May 9, 2019 · 334.30 States that the romex is required to be supported and secured every 4.5' min. In an attic where it is accessible, this is the method we use. A house that has a flat roof …
Romex Connectors installed from the inside of the box
Jul 23, 2007 · Does anyone know of a romex connector that can be installed from the inside of an EXISTING junction box. I can't access the outside of the box without opening up the drywall, …
Romex outdoor application | Information by Electrical …
Jan 4, 2023 · Can indoor romex be used in an outdoor structure if the ceiling is enclosed. Everything else on the structure is open. it will basically be cedar covering the rafter bays.